IEEE Transactions on Automatic Control · 1994 · 273 citations · 15 references
EngineeringSystems EngineeringAnalog ElectronicsProcess ControlSystem DynamicsAdaptive ControlControl TheoryDigital Signal ProcessingFrequency ResponseHarmonic AnalysisLaplace Transform MethodsHarmonic GenerationHarmonic MitigationHarmonic ProductionHarmonic ReductionHarmonicsInternal Model PrincipleLaplace TransformLaplace Transform Analysis
The paper investigates the generation of harmonics in adaptive feedforward cancellation schemes. Specifically, it is shown that an algorithm designed to reject a certain number of frequency components may in fact be capable of reducing higher-order harmonics as well. This effect originates in the time-variation of the adaptive parameters. A consequence is that the adaptive system may perform better than the algorithm with the fixed, ideal parameters. Surprisingly, the response to higher-order harmonics can be calculated precisely, using a Laplace transform analysis. The origin of the numerical procedure is in the equivalence between the adaptive feedforward cancellation scheme and a control scheme based on the internal model principle. The implication of the results on design and implementation issues is discussed.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
15
The internal model principle of control theory
Bruce A. Francis, W.M. Wonham · Automatica · 1976 · 2.8K citations
Adaptive control stability, convergence, and robustness
Bo Egardt · Automatica · 1993 · 2.7K citations