2011 · 15 citations · 6 references
EngineeringMaterials EngineeringMaterials ScienceElectronic MaterialsSemiconductor DevicesSensorsCapacitive SensingDevice CharacterizationMechanical SensorsPhysical SensorsPressure MeasurementPressure SensorsCapacitive Pressure SensingCapacitive Pressure SensorsCapacitive SensorsHigh-temperature Pressure SensorsPressure SensingPressure Sensor SensitivitySilicon CarbideThermal Mismatch
We have studied the effect of substrate material related to thermal mismatch for silicon carbide (SiC) diaphragm-based capacitive pressure sensors. Two sets of devices, with identical dimensions and fabrication processes were made on poly-SiC and Si substrates. Designed for a maximum pressure of 4.83 MPa (700 psi), these devices were operated in small-deflection mode and tested at room temperature and 500°C. At room temperature, the SiC- and Si-substrate devices showed sensitivities of 6.5E-04 and 6.1E-04 fF/Pa, nonlinearities of 5.0% and 3.9%, and resolutions of 0.2% and 0.3%, respectively. At 500°C, the SiC- and Si-substrate devices showed sensitivities of 1.2E-02 and 1.1E-02 fF/Pa, nonlinearities of 2.6% and 3.8%, and resolutions of 0.5% and 1.8%, respectively. For the chosen design parameters, the results show little influence of substrate material on sensor performance.
6
High-Temperature Single-Crystal 3C-SiC Capacitive Pressure Sensor
Darrin J. Young, Jian Du, Christian A. Zorman et al. · IEEE Sensors Journal · 2004 · 221 citations