New acceleration factors for temperature, humidity, bias testing

Neil Sbar, R. P. Kozakiewicz

IEEE Transactions on Electron Devices · 1979 · 43 citations · 14 references

Concepts

Abstract

New temperature-humidity acceleration factors for surface conductance ( <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">G</tex> ) were determined. These can be used to relate device life in a high-stress laboratory environment to device life in a normal-use environment. Analytical expressions for the acceleration factors were derived for both encapsulated and unencapsulated test specimens. Lower acceleration factors were predicted for specimens encapsulated with DC 3-6550 RTV silicone rubber than for unencapsulated specimens. The new acceleration factors were used to predict failure rates due to electrolytic conduction on active devices.

References

14