Biotechnology and Bioengineering · 1981 · 18 citations · 5 references
EngineeringAnimal SciencesBioseparationsDownstream ProcessingSeparation ProcessesDialyzer MembranesMembrane FiltrationHollow Fiber MembranesOperating ConditionsOptimization Of Operating ConditionsUltrafiltrationUltrafiltration MembranesUltrafiltration TreatmentVacuum Evaporation
Abstract Pilot‐scale investigations into the application of ultrafiltration (UF) for concentrating bovine blood or a mixture of bovine and ovine blood are described. Tests were carried out in an Iopor 6CL UF system and a Romicon (hollow fiber) UF system. Optimal operating conditions for these two system were evaluated. Starting from a 18–20% TS lood concentration final concentrations of 28–30% TS were achieved. The lopor system was found to be more suited for processing blood and the average flux values obtained indicated UF to be a more economical process for concentrating blood than vacuum evaporation.
5