Concepedia

Publication | Closed Access

EUV lithography optics for sub-9nm resolution

66

Citations

2

References

2015

Year

Abstract

EUV lithography for resolution below 9 nm requires the numerical aperture of the projection optics to be significantly larger than 0.45. A configuration of 4x magnification, full field size and 6’’ reticle is not feasible anymore. The increased chief ray angle and higher NA at reticle lead to non-acceptable shadowing effects, which can only be controlled by increasing the magnification, hence reducing the system productivity. We demonstrate that the best compromise in imaging, productivity and field split is a so-called anamorphic magnification and a half field of 26 x 16.5 mm². We discuss the optical solutions for anamorphic high-NA lithography.

References

YearCitations

Page 1