Power Loss, System Efficiency, and Leakage Current Comparison Between Si IGBT VFD and SiC FET VFD With Various Filtering Options

Mahesh Swamy, Jun-Koo Kang, Kohei Shirabe

IEEE Transactions on Industry Applications · 2015 · 146 citations · 8 references

Concepts

Abstract

SiC devices are gaining acceptance in the motor drive industry. This paper compares the power loss and efficiency between two options that can be used with SiC-based variable frequency drives (VFDs). In the first option, the SiC VFD is equipped with an output sine-wave filter with carrier frequency at 50 kHz. A dv/dt filter is used for the second option with the carrier frequency reduced to 8 kHz. Both options are compared with a standard Si insulated-gate bipolar transistor (IGBT) VFD operating at a carrier frequency of 8 kHz with no output filter. The focus of this paper is to present different filtering options for SiC VFDs. The dv/dt filter is designed to meet the same specification as that of the standard Si IGBT VFD with no output filter, so as to present a fair comparison between a standard Si IGBT VFD and the next-generation SiC VFD. Results using a 460-V 11-kW system show that the SiC VFD with an output sine-wave filter has a lower efficiency compared with SiC VFD with a dv/dt filter. Influence of the various filtering options on leakage current in the motor drive system has also been studied, and the results are presented in this paper.

References

8