Analytical Chemistry · 2005 · 28 citations · 13 references
Life SciencesBiotechnologyMolecular BiologyPlant BiotechnologyPlant GeneticsSequence AnalysisBioanalytical Method ValidationPolymerase Chain ReactionCompetitive Polymerase Chain ReactionInternal StandardsNucleic Acid Hybridization AssaysPolymerase Chain Reaction (Pcr) AssaysPolymerase Chain Reaction AnalysisPolymerase Chain Reaction Product DetectionQuantitative Pcr DetectionThroughput
Quantitative competitive polymerase chain reaction (PCR), especially the double competitive PCR methods (DC-PCR), have evolved as reliable approaches to quantification of genetically modified organisms (GMO) in food. However, DC-PCR is a low-throughput method because it requires titration of each sample with various amounts of a competitive internal standard, a protocol that involves several PCRs per sample followed by electrophoresis and densitometry. To address this drawback, we have developed a new method for GMO quantification, namely, a high-throughput double quantitative competitive PCR (HT-DCPCR). In HT-DCPCR, electrophoresis and densitometry are replaced by a rapid, microtiter well-based bioluminometric hybridization assay and there is no need for titration of each sample. The determination of GM soya was chosen as a model. We have constructed internal standards (DNA competitors) both for the 35S promoter sequence and for a plant-specific reference gene (lectin). The competitors have identical size and share the same primer binding sites with the target sequences but differ in a 24-bp internal segment. Each target sequence (35S and lectin) is coamplified with a constant amount (1000 copies) of the respective competitor. The four amplified fragments are hybridized with specific probes and captured on a universal solid phase to achieve simplicity and high throughput. The hybrids are determined by using streptavidin conjugated to the photoprotein aequorin. The ratio of the luminescence values obtained for the target and the competitor is linearly related to the starting amount of target DNA. The limit of quantification for the 35S promoter is 24 copies. The proposed method was evaluated by determining the GMO content of soybean powder certified reference materials. Also HT-DCPCR was compared to real-time PCR in a variety of real samples.
13
Elke Anklam, Ferruccio Gadani, Petra Heinze et al. · European Food Research and Technology · 2002 · 299 citations
Marc Vaïtilingom, Hans Pijnenburg, François Gendre et al. · Journal of Agricultural and Food Chemistry · 1999 · 217 citations
Life Sciences, Agricultural Biotechnology, Biotechnology +14
Philipp Mayer, Wouter H. J. Vaes, Joop L. M. Hermens · Analytical Chemistry · 1999 · 181 citations
Natural Sciences, Chemical Engineering, Materials Science +13