IEEE Transactions on Nuclear Science · 1982 · 41 citations · 3 references
EngineeringAerospace EngineeringElectrical EngineeringMicroelectronicsRadiation PhysicsSemiconductor DevicesElectron DosimetryRadiation Damage In MaterialsRadiation HardeningRadiation Hazard AssessmentRadiation Risk AssessmentRadiation SensitivityCmos ReliabilityComponent-level Radiation TestingRadiation DamageRadiation Damage EffectsRadiation EffectsRadiation Effects On ReliabilityRadiation TestingTotal Ionizing Dose Effects
The results of laboratory tests to determine the radiation damage effects induced on MOS devices from Co-60, electron, and proton radiation are reported. The tests are performed to establish the relationship between the Co-60 gamma rays and the level of damage to the MOS devices in regards to different damages which can be expected with the electron and particle bombardments experienced in space applications. CMOS devices were exposed to the Co-60 gamma rays, 1 MeV electrons, and 1 MeV protons while operating at 3, 10, and 15 V. The test data indicated that the Co-60 source was reliable for an initial evaluation of the electron damages up to 2 MeV charge. A correction factor was devised for transferring the Co-60 measurements to proton damages, independent of bias and transistor types, for any orbit or environment.
3
Hole and electron transport in SiO2 films
O. L. Curtis, J. R. Srour, Kun‐An Chiu · Journal of Applied Physics · 1974 · 110 citations