Applied Physics Letters · 2014 · 38 citations · 19 references
EngineeringElectrical EngineeringMaterials ScienceNanotechnologySemiconductor DevicesSemiconductor MaterialsElectron DiffractionElectron MicroscopyQuantum Well DevicesQuantum WellsStrain MeasurementTransmission Electron MicroscopyDiffraction Pattern AnalysisElectron Diffraction Pattern AnalysisPrecession Electron DiffractionStrain EffectsStrain MappingStrain MeasuresTransmission Electron DiffractionTransmission Electron Microscopy Strain Mapping
Precession electron diffraction is an efficient technique to measure strain in nanostructures by precessing the electron beam, while maintaining a few nanometre probe size. Here, we show that an advanced diffraction pattern treatment allows reproducible and precise strain measurements to be obtained using a default 512 × 512 DigiSTAR off-axis camera both in advanced or non-corrected transmission electron microscopes. This treatment consists in both projective geometry correction of diffraction pattern distortions and strain Delaunay triangulation based analysis. Precision in the strain measurement is improved and reached 2.7 × 10−4 with a probe size approaching 4.2 nm in diameter. This method is applied to the study of the strain state in InGaAs quantum-well (QW) devices elaborated on Si substrate. Results show that the GaAs/Si mismatch does not induce in-plane strain fluctuations in the InGaAs QW region.
19
NIH Image to ImageJ: 25 years of image analysis
Caroline A Schneider, Wayne Rasband, Kevin W. Eliceiri · Nature Methods · 2012 · 65.2K citations
Eli Peli · Journal of the Optical Society of America A · 1990 · 1.3K citations
Eli Peli · Annual Meeting Optical Society of America · 1988 · 942 citations