Nucleic Acids Research · 2015 · 249 citations · 75 references
EngineeringBioengineeringBiotechnologyBiosensorsMetabolic EngineeringSynthetic BiologyBiological SensorsBiosensor DesignCell-based BiosensorsEnzyme-based BiosensorsMetabolic Pathway EngineeringSynthetic Gene CircuitsBiosensor DevelopmentFluorescent BiosensingFluorescent Reporter SystemsFluorescent SensingFluorescent SensorsHeterologous Pathway ExpressionSynthetic Expression CircuitsSynthetic Gene Circuit Biosensors
Inducible transcriptional regulators enable precise gene control, yet only a few are well characterized, constraining the complexity of engineered biological systems. The study aims to demonstrate biosensor utility by using a glucarate sensor to monitor product formation and identify better enzyme variants in a heterologous glucarate pathway. We applied a characterization pipeline to four genetically encoded sensors for acrylate, glucarate, erythromycin, and naringenin, measuring dose–response, induction kinetics, and single‑cell activation to relate chemical concentration to protein expression, and then used the glucarate sensor to monitor product formation in a heterologous pathway. The sensors activate orthogonally, enabling independent control of three fluorescent proteins and eight distinct transcriptional states, and doubling the number of well‑characterized inducible systems facilitates complex synthetic circuits and high‑throughput screening of metabolic enzymes.
Characterization and standardization of inducible transcriptional regulators has transformed how scientists approach biology by allowing precise and tunable control of gene expression. Despite their utility, only a handful of well-characterized regulators exist, limiting the complexity of engineered biological systems. We apply a characterization pipeline to four genetically encoded sensors that respond to acrylate, glucarate, erythromycin and naringenin. We evaluate how the concentration of the inducing chemical relates to protein expression, how the extent of induction affects protein expression kinetics, and how the activation behavior of single cells relates to ensemble measurements. We show that activation of each sensor is orthogonal to the other sensors, and to other common inducible systems. We demonstrate independent control of three fluorescent proteins in a single cell, chemically defining eight unique transcriptional states. To demonstrate biosensor utility in metabolic engineering, we apply the glucarate biosensor to monitor product formation in a heterologous glucarate biosynthesis pathway and identify superior enzyme variants. Doubling the number of well-characterized inducible systems makes more complex synthetic biological circuits accessible. Characterizing sensors that transduce the intracellular concentration of valuable metabolites into fluorescent readouts enables high-throughput screening of biological catalysts and alleviates the primary bottleneck of the metabolic engineering design-build-test cycle.
75
Enzymatic assembly of DNA molecules up to several hundred kilobases
Daniel G. Gibson, Lei Young, Ray-Yuan Chuang et al. · Nature Methods · 2009 · 10.9K citations
Functional profiling of the Saccharomyces cerevisiae genome
Guri Giaever, Angela Chu, Li Ni et al. · Nature · 2002 · 4.5K citations
Engineering and characterization of a superfolder green fluorescent protein
J.D. Pédelacq, Stéphanie Cabantous, Timothy H. Tran et al. · Nature Biotechnology · 2005 · 2.5K citations