IEEE Journal of Biomedical and Health Informatics · 2024 · 26 citations · 38 references
MedicineNeuroscienceRehabilitation MedicineRehabilitationRehabilitation EngineeringStroke RehabilitationBrain-computer InterfacesHand RehabilitationNeurological RehabilitationRehabilitation RoboticsRobotic RehabilitationVisual Evoked PotentialsBrain-computer Interface Signal ProcessingCanonical Correlation AnalysisHand Rehabilitation RoboticsHybrid Brain-computer InterfacesOnline Controlled ExperimentsPost-stroke Hand RehabilitationPost-stroke Upper-limb RehabilitationSoft Robotic Devices
Soft robotic glove controlled by a brain-computer interface (BCI) have demonstrated effectiveness in hand rehabilitation for stroke patients. Current systems rely on static visual representations for patients to perform motor imagination (MI) tasks, resulting in lower BCI performance. Therefore, this study innovatively used MI and high-frequency steady-state visual evoked potential (SSVEP) to construct a friendly and natural hybrid BCI paradigm. Specifically, the stimulation interface sequentially presented decomposed action pictures of the left and right hands gripping a ball, with the pictures flashing at specific stimulation frequencies (left: 34 Hz, right: 35 Hz). Integrating soft robotic glove as feedback, we established a comprehensive "peripheral - central - peripheral" hand rehabilitation system to facilitate the hand rehabilitation of patients. Filter bank common spatial pattern (FBCSP) and filter bank canonical correlation analysis (FBCCA) algorithms were used to identify MI and SSVEP signals, respectively. Additionally, we proposed a novel fusion algorithm to decide the final output of the system. The feasibility of the proposed system was validated through online experiments involving 12 healthy subjects and 9 stroke patients, achieving accuracy rates of 95.83 ± 6.83% and 63.33 ± 10.38, respectively. The accuracy of MI and SSVEP in 12 healthy subjects reached 81.67 ± 15.63% and 95.14 ± 7.47%, both lower than the accuracy after fusion, these results confirmed the effectiveness of the proposed algorithm. The accuracy rate was more than 50% in both healthy subjects and patients, confirming the effectiveness of the proposed system.
38
David H. Brainard · Spatial Vision · 1997 · 20.1K citations
Valery L. Feigin, Benjamin Stark, Catherine O. Johnson et al. · The Lancet Neurology · 2021 · 7.6K citations · Full text
World Stroke Organization (WSO): Global Stroke Fact Sheet 2022
Valery L. Feigin, Michael Brainin, Bo Norrving et al. · International Journal of Stroke · 2022 · 2.8K citations
Filter Bank Common Spatial Pattern (FBCSP) in Brain-Computer Interface
Kai Keng Ang, Zheng Yang Chin, Haihong Zhang et al. · 2008 · 1.4K citations