Applied Ergonomics · 2024 · 28 citations · 29 references
ComputingComputer ScienceRadiologyArtificial IntelligenceDiagnostic ImagingDiagnostic RadiologyArtificial Intelligence AdoptionComputer-aided DiagnosisRadiology InformaticsRadiology Information SystemsSystem ImplementationWorkflow IntegrationArtificial Intelligence-based DetectionComputer-aided DetectionImaging Workflow ManagementRadiologist WorkflowRadiology Artificial IntelligenceRadiology Workflow ManagementSociotechnical SystemsTechnology Acceptance
In healthcare, artificial intelligence (AI) is expected to improve work processes, yet most research focuses on the technical features of AI rather than its real-world clinical implementation. To evaluate the implementation process of an AI-based computer-aided detection system (AI-CAD) for prostate MRI readings, we interviewed German radiologists in a pre-post design. We embedded our findings in the Model of Workflow Integration and the Technology Acceptance Model to analyze workflow effects, facilitators, and barriers. The most prominent barriers were: (i) a time delay in the work process, (ii) additional work steps to be taken, and (iii) an unstable performance of the AI-CAD. Most frequently named facilitators were (i) good self-organization, and (ii) good usability of the software. Our results underline the importance of a holistic approach to AI implementation considering the sociotechnical work system and provide valuable insights into key factors of the successful adoption of AI technologies in work systems.
29
Allison Tong, Peter Sainsbury, Jonathan C. Craig · International Journal for Quality in Health Care · 2007 · 41.6K citations · Full text