Experimental Heat Transfer · 2023 · 13 citations · 34 references
EngineeringMaterials EngineeringMechanical EngineeringHeat TransferThermal AnalysisThermodynamicsHeat ExchangersHeat FlowHeat Transfer In FluidsThermal DesignThermal ManagementThermal Properties Of MaterialsCoil Heat TransferEntropy Generation AnalysisEntropy Generation MinimizationHeat Exchanger DesignHeat Transfer EnhancementHydrothermal Performance AnalysisHydrothermal ProcessingReynolds Number
An experimental study involving tapered wire coil inserts in a double-tube heat exchanger using water-based phase change material (PCM)-dispersed mono/hybrid nanofluids is conducted. The effects of the wire coils (WC) with nanofluids on the hydrothermal performance of this system are studied for different coil arrangements: converging wire coils (CWC), diverging wire coils (DWC), and converging-diverging wire coils (CDWC) and different Reynolds numbers. The experimental results indicate that among all the tested coil arrangements, the DWC presents a higher thermal performance factor (TPF) than the other arrangements. Using the DWC, the TPF of the Al2O3+PCM hybrid nanofluid is augmented by 3.98%, 9.61%, and 3.04% as compared to that for the plain wire coil (PWC), CWC, and CDWC, respectively. Besides, the DWC configuration exhibits the minimum entropy generation among all arrangements. For the Al2O3+PCM hybrid nanofluid using the DWC, the entropy generation is decreased by approximately 13.36%, 9.78%, and 5.78% as compared to that of the PWC, CWC, and CDWC at a volumetric flow rate of 15 lpm.