Soft Robotics · 2022 · 16 citations · 26 references
MedicineSurgeryUrologyActuatorsUrodynamicsUrologic SurgeryBladder SurgeryDetrusor Muscle FunctionHydraulic ActuatorsUrinary IncontinenceVoiding FunctionBellows ActuatorsBiocompatible MaterialsBladder DiversionBladder SubstitutionBladder Voiding EfficiencyDetrusor Muscle MechanicsElastomeric Bellows ActuatorsPrecision Actuation
The gold standard treatment for bladder cancer is radical cystectomy that implies bladder removal coupled to urinary diversions. Despite the serious complications and the impossibility of controlled active voiding, bladder substitution with artificial systems is a challenge and cannot represent a real option, yet. In this article, we present hydraulic artificial detrusor prototypes to control and drive the voiding of an artificial bladder (AB). These prototypes rely on two actuator designs ( origami and bellows ) based either on negative or positive operating pressure, to be combined with an AB structure. Based on the bladder geometry and size, we optimized the actuators in terms of contraction/expansion performances, minimizing the liquid volume required for actuation and exploring different actuator arrangements to maximize the voiding efficiency. To operate the actuators, an ad hoc electrohydraulic circuit was developed for transferring liquid between the actuators and a reservoir, both of them intended to be implanted. The AB, actuators, and reservoir were fabricated with biocompatible flexible thermoplastic materials by a heat-sealing process. We assessed the voiding efficiency with benchtop experiments by varying the actuator type and arrangement at different simulated patient positions (horizontal, 45° tilted, and vertical) to identify the optimal configuration and actuation strategy. The most efficient solution relies on two bellows actuators anchored to the AB. This artificial detrusor design resulted in a voiding efficiency of about 99%, 99%, and 89%, in the vertical, 45° tilted, and horizontal positions, respectively. The relative voiding time was reduced by about 17, 24, and 55 s compared with the unactuated bladder.
26
Fluid-driven origami-inspired artificial muscles
Shuguang Li, Daniel M. Vogt, Daniela Rus et al. · Proceedings of the National Academy of Sciences · 2017 · 732 citations · Full text
Soft robotic sleeve supports heart function
Ellen T. Roche, Markus A. Horvath, Isaac Wamala et al. · Science Translational Medicine · 2017 · 419 citations · Full text
A healthy bladder: a consensus statement
Emily S. Lukacz, Carolyn M. Sampselle, M Gray et al. · International Journal of Clinical Practice · 2011 · 155 citations · Full text
Medicine, Health Promotion, Urology +17