Post irradiation effects (PIE) in integrated circuits (CMOS)

David C. Shaw, Lynn E. Lowry, C. E. Barnes, Milad Zakharia, S. Agarwal, B.G. Rax

IEEE Transactions on Nuclear Science · 1991 · 12 citations · 21 references

Concepts

Abstract

Post-irradiation effects (PIE) ranging from normal recovery to catastrophic failure have been observed in integrated circuits during the PIE period. Data presented show failure due to rebound after a 10 krad(Si) dose. In particular, five device types are investigated with varying PIE response. Special attention has been given to the HI 1-507A analog multiplexer because its PIE response is extreme. X-ray diffraction has been uniquely employed to measure physical stress in the HI 1-507A metallization. An attempt has been made to show a relationship between stress relaxation and radiation effects. All data presented support the current MIL-STD Method 1019.4 but demonstrate the importance of performing PIE measurements, even when mission doses are as low as 10 krad(Si).< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

References

21