IEEE Transactions on Nuclear Science · 1991 · 12 citations · 21 references
EngineeringElectrical EngineeringMaterials ScienceElectronic MaterialsMicroelectronicsRadiation MeasurementHigh-dose Radiation EffectsRadiation Damage In MaterialsRadiation HardeningRadiation-resistant MaterialsResidual StressIrradiation EffectsMetallizationRadiation Damage EffectsRadiation EffectsRadiation Effects On ReliabilityRadiation TestingStress Relaxation MechanismsX-ray Diffraction Analysis
Post-irradiation effects (PIE) ranging from normal recovery to catastrophic failure have been observed in integrated circuits during the PIE period. Data presented show failure due to rebound after a 10 krad(Si) dose. In particular, five device types are investigated with varying PIE response. Special attention has been given to the HI 1-507A analog multiplexer because its PIE response is extreme. X-ray diffraction has been uniquely employed to measure physical stress in the HI 1-507A metallization. An attempt has been made to show a relationship between stress relaxation and radiation effects. All data presented support the current MIL-STD Method 1019.4 but demonstrate the importance of performing PIE measurements, even when mission doses are as low as 10 krad(Si).< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
21
Physics of Semiconductor Devices
Samarth Jain, S. Radhakrishna · 1987 · 4.2K citations
Physical Mechanisms Contributing to Device "Rebound"
J.R. Schwank, P.S. Winokur, P. J. McWhorter et al. · IEEE Transactions on Nuclear Science · 1984 · 360 citations