Journal of Robotics and Mechatronics · 2021 · 19 citations · 27 references
Gait AnalysisEngineeringDepth SensorHealthy SubjectsHuman Pose EstimationConcordance Correlation Coefficient3D Pose EstimationWearable TechnologyMovement BiomechanicsKinect Skeleton AlgorithmPosture3D Body ScanningMovement AnalysisKinesiologyMotion CaptureHuman MotionKinematicsPhysical MedicineGeometric ModelingHealth SciencesMachine VisionRobotic TechnologyRehabilitationComputer Vision3D ReconstructionHuman MovementRobotics
Kinect has been utilized as a cost-effective, easy-to-use motion capture sensor using the Kinect skeleton algorithm. However, a limited number of landmarks and inaccuracies in tracking the landmarks’ positions restrict Kinect’s capability. In order to increase the accuracy of motion capturing using Kinect, joint use of the Kinect skeleton algorithm and Kinect-based marker tracking was applied to track the 3D coordinates of multiple landmarks on human. The motion’s kinematic parameters were calculated using the landmarks’ positions by applying the joint constraints and inverse kinematics techniques. The accuracy of the proposed method and OptiTrack (NaturalPoint, Inc., USA) was evaluated in capturing the joint angles of a humanoid (as ground truth) in a walking test. In order to evaluate the accuracy of the proposed method in capturing the kinematic parameters of a human, lower body joint angles of five healthy subjects were extracted using a Kinect, and the results were compared to Perception Neuron (Noitom Ltd., China) and OptiTrack data during ten gait trials. The absolute agreement and consistency between each optical system and the robot data in the robot test and between each motion capture system and OptiTrack data in the human gait test were determined using intraclass correlations coefficients (ICC3). The reproducibility between systems was evaluated using Lin’s concordance correlation coefficient (CCC). The correlation coefficients with 95% confidence intervals (95%CI) were interpreted substantial for both OptiTrack and proposed method (ICC > 0.75 and CCC > 0.95) in humanoid test. The results of the human gait experiments demonstrated the advantage of the proposed method (ICC > 0.75 and RMSE = 1.1460°) over the Kinect skeleton model (ICC < 0.4 and RMSE = 6.5843°).
27
A Concordance Correlation Coefficient to Evaluate Reproducibility
Biometrics · 1989 · 8.5K citations
Real-time human pose recognition in parts from single depth images
Jamie Shotton, Andrew Fitzgibbon, Mat Cook et al. · 2011 · 3.5K citations
A gait analysis data collection and reduction technique
Roy B. Davis, Sylvia Õunpuu, Dennis Tyburski et al. · Human Movement Science · 1991 · 3K citations