IEEE Transactions on Medical Robotics and Bionics · 2021 · 32 citations · 45 references
EngineeringBiomedical EngineeringRobotics EngineeringActuatorsBiomechanicsMovement AnalysisBiomechanical AnalysisHip BiomechanicsJoint BiomechanicsLower Limb BiomechanicsRehabilitation RoboticsRobotic ExoskeletonsExoskeleton BiomechanicsExoskeletonsGround Reaction ForcesInverse Dynamics ModelingLower Extremity KinematicsMechanical PowerParameter IdentificationSitting Biomechanics
Prior work on regenerative exoskeletons and prostheses has focused on level‑ground walking. The study analyzes stand‑to‑sit joint mechanical power to estimate biomechanical energy for electrical regeneration and highlights the need to extend analyses to seniors and rehabilitation patients. Nine healthy adults performed 20 stand‑to‑sit cycles while kinematics and ground‑reaction forces were recorded, and inverse dynamics with subject‑specific parameters were used to compute and integrate joint mechanical power. The hip generates the greatest negative power (≈1.8 W/kg) and work (≈0.35 J/kg) during stand‑to‑sit, yielding an estimated 26 J of recoverable electrical energy—about 30 % more than the 19 J per stride achievable during walking.
Previous studies of robotic exoskeletons and prostheses with regenerative actuators have focused on level-ground walking. Here we analyzed the lower-limb joint mechanical power during stand-to-sit movements using inverse dynamics to estimate the biomechanical energy available for electrical regeneration. Nine subjects performed 20 sitting and standing movements while lower-limb kinematics and ground reaction forces were measured. Subject-specific body segment parameters were estimated using parameter identification. Joint mechanical power was calculated from joint torques and rotational velocities and numerically integrated over time to estimate the joint biomechanical energy. The hip absorbed the largest peak negative mechanical power (1.8 ± 0.5 W/kg), followed by the knee (0.8 ± 0.3 W/kg) and ankle (0.2 ± 0.1 W/kg). Negative mechanical work on the hip, knee, and ankle joints per stand-to-sit movement were 0.35 ± 0.06 J/kg, 0.15 ± 0.08 J/kg, and 0.02 ± 0.01 J/kg, respectively. Assuming known regenerative actuator efficiencies (i.e., maximum 63%), robotic exoskeletons and prostheses could regenerate ~26 Joules of electrical energy while sitting down, compared to ~19 Joules per walking stride. Given that these regeneration performance calculations are based on healthy young adults, future research should include seniors and/or rehabilitation patients to better estimate the biomechanical energy available for electrical regeneration.
45