2014 Solid-State, Actuators, and Microsystems Workshop Technical Digest · 2014 · 10 citations · 5 references
EngineeringMechanical EngineeringMechatronics EngineeringInstrumentationMechatronicsMicroelectromechanical SystemsCalibrationMems CharacterizationMems DesignMems ModelingMems SimulationMems TestingGyroscope CharacterizationGyroscopesMechanical NoiseMechanical Noise AnalysisMechanical Noise SourcesMechanical System NoiseNavigationThermal Noise
This paper presents detailed performance status and projections for the silicon MEMS Quadruple Mass Gyroscope (QMG) -a unique high Q, lumped mass, mode-symmetric Class II Coriolis Vibratory Gyroscope (CVG) with interchangeable whole angle, self-calibration, and force rebalance mechanizations. Analysis of a QMG sealed without getter with a Q-factor of 1e3 reveals an Angle Random Walk (ARW) of 0.02 deg/rt-hr limited only by the fundamental Mechanical-Thermal Noise (MTN). Propagation of a detailed noise model to a QMG sealed with getter at a Q-factor of 1e6 (previously demonstrated) showed better than Navigation Grade ARW of 0.001 deg/rt-hr. Combination of the very low ARW with the mode-symmetry enabled self-calibration substantiates the navigation grade performance capacity of the Si-MEMS QMG.
5
Mechanical-thermal noise in MEMS gyroscopes
R.P. Leland · IEEE Sensors Journal · 2005 · 157 citations