Drug Testing and Analysis · 2018 · 17 citations · 24 references
PharmacyBiochemistryToxicologyAnalytical ToxicologyForensic ToxicologyMetabolomicsBioanalytical Method ValidationBiomarker AnalysisMass SpectrometryMass Spectrometry-based MetabolomicsMetabolic EvaluationUntargeted MetabolomicsBiomarkersMass Spectrometry MetabolomicsProtein PrecipitationToxicological Analysis Of UrineUrinary Metabolite ProfilingUrine BiomarkersUrine ChemistriesUrine Ph Evaluation
Abstract Urine adulteration to circumvent positive drug testing is a fundamental challenge for toxicological laboratories all over the world. Untargeted mass spectrometry (MS) methods used in metabolomics had previously revealed uric acid (UA), histidine, methylhistidine, and their oxidation products, for example 5‐hydroxyisourate (HIU) as potential biomarkers for urine adulteration using potassium nitrite (KNO 2 ). These markers should be further evaluated for their reliability, stability, and routine applicability. Influence of KNO 2 concentration, urinary pH, reaction time, and stability at room temperature, 4°C, and − 20°C was determined in urine under varying conditions. Analysis was performed after protein precipitation with acetonitrile by liquid chromatography–high resolution mass spectrometry (LC–HRMS). Receiver operating characteristics (ROC) analysis was applied for cut‐off evaluation after biomarker quantification ( n = 100 per group). Blinded measurements ( n = 50) were performed to check the general applicability to identify adulterated samples under routine conditions. The higher the adulterant concentration, the lower the concentrations of histidine, methylhistidine, and UA. In return, amounts of their oxidation products increased. Highest changes were observed under weak acid conditions (pH 4–5). Storage at −20°C ensured sufficient stability for all oxidative markers over one month. ROC evaluated biomarker performance and application to unknown samples revealed satisfying results, with HIU as the most suitable biomarker (positive predictive value (PPV) 100%), followed by UA (PPV 93%). HIU and UA proved suitable markers to identify urine adulteration using KNO 2 and are ready for implementation into routine MS procedures.
24
MetaboAnalyst 4.0: towards more transparent and integrative metabolomics analysis
Jasmine Chong, Othman Soufan, Carin Li et al. · Nucleic Acids Research · 2018 · 3.8K citations · Full text
HMDB 4.0: the human metabolome database for 2018
David S. Wishart, Yannick Djoumbou-Feunang, Ana Marcu et al. · Nucleic Acids Research · 2017 · 3.6K citations · Full text
Souhaila Bouatra, Farid Aziat, Rupasri Mandal et al. · PLoS ONE · 2013 · 1.4K citations · Full text
Life Sciences, Biochemistry, Mass Spectrometric Analysis +16
Free radical metabolite of uric acid.
Kirk R. Maples, Ronald P. Mason · Journal of Biological Chemistry · 1988 · 228 citations · Full text