<b>Application of high‐speed counter‐current chromatography and HPLC to separate and purify of three polyacetylenes from <i>Platycodon grandifloru</i></b><i>m</i>

Bao Chen, Zhengbo Liu, Yuwei Zhang, Wei Li, Yan‐Jun Sun, Yan‐Jun Sun, Yu‐Fang Wang, Yanhua Wang

Journal of Separation Science · 2017 · 20 citations · 25 references

Concepts

Abstract

Three polyacetylenes were isolated and purified from Platycodon grandiflorum A. DC for the first time by high-speed counter-current chromatography using a two-phase solvent system composed of hexane/ethyl acetate/methanol/water (1:31:1:31, v/v/v/v) and high-performance liquid chromatography with an Agilent ZORBAX® SB-C18 column (4.6 mm × 150 mm, 5 μm). After separation by high-speed counter-current chromatography and high-performance liquid chromatography, we obtained 3.5 mg of platetyolin A, 4.1 mg of platetyolin B, and 18.1 mg of lobetyolin with purities of 97.2, 96.7, and 96.9%, respectively. The purity of each compound was assessed by high-performance liquid chromatography and the chemical structures were evaluated by high-resolution electrospray ionization time-of-flight mass spectrometry and one- and two-dimensional NMR spectroscopy. Among the isolated compounds, platetyolin A and platetyolin B are newly reported compounds.

References

25