The AAPS Journal · 2017 · 30 citations · 24 references
MedicinePharmacologyToxicologyClinical PharmacologyElectrophysiologyPharmacovigilanceCardiac Ion ChannelsCardiovascular Drug SafetyElectrophysiological ModelingIon Channel PharmacologyIon Channel ToxicityPharmacokinetic SimulationCardiac Electrophysiology ModelingCardiac Electrophysiology SimulationClinical Toxicology ApplicationsConcentration-qt RelationshipDrug Concentration PredictionElectrophysiological SafetyQt Interval Prolongation ModelingQuantitative Systems Toxicology
A quantitative systems toxicology (QST) model for citalopram was established to simulate, in silico, a ‘virtual twin’ of a real patient to predict the occurrence of cardiotoxic events previously reported in patients under various clinical conditions. The QST model considers the effects of citalopram and its most notable electrophysiologically active primary (desmethylcitalopram) and secondary (didesmethylcitalopram) metabolites, on cardiac electrophysiology. The in vitro cardiac ion channel current inhibition data was coupled with the biophysically detailed model of human cardiac electrophysiology to investigate the impact of (i) the inhibition of multiple ion currents (I Kr , I Ks , I CaL ); (ii) the inclusion of metabolites in the QST model; and (iii) unbound or total plasma as the operating drug concentration, in predicting clinically observed QT prolongation. The inclusion of multiple ion channel current inhibition and metabolites in the simulation with unbound plasma citalopram concentration provided the lowest prediction error. The predictive performance of the model was verified with three additional therapeutic and supra-therapeutic drug exposure clinical cases. The results indicate that considering only the hERG ion channel inhibition of only the parent drug is potentially misleading, and the inclusion of active metabolite data and the influence of other ion channel currents should be considered to improve the prediction of potential cardiac toxicity. Mechanistic modelling can help bridge the gaps existing in the quantitative translation from preclinical cardiac safety assessment to clinical toxicology. Moreover, this study shows that the QST models, in combination with appropriate drug and systems parameters, can pave the way towards personalised safety assessment.
24
AN ANALYSIS OF THE TIME‐RELATIONS OF ELECTROCARDIOGRAMS.
H. C. Bazett · Annals of Noninvasive Electrocardiology · 1997 · 808 citations
Medicine, Cardiology, Physiology +12
William Crumb, José Vicente, Lars Johannesen et al. · Journal of Pharmacological and Toxicological Methods · 2016 · 296 citations · Full text
Medicine, Cardiology, Pharmacology +13