BMC Infectious Diseases · 2017 · 20 citations · 20 references
Life SciencesInfectious DiseasesMicrobiologyAntimicrobial ResistanceInfection PreventionMedical MicrobiologyAntibiotic ResistanceAntimicrobial Resistance PreventionBacterial InfectionsContact PrecautionsHealthcare-associated Infection PreventionMicrobial ContaminationBacterial Contamination PreventionContact With Contaminated SurfacesDisposable GlovesHealthcare Surface HygieneHealthcare-associated Infection RiskHospital Surface ContaminationPatient Hand HygieneSurface Contact Contamination
Reduction of accidental contamination of the near-patient environment has potential to reduce acquisition of healthcare-associated infection(s). Although medical gloves should be removed when soiled or touching the environment, compliance is variable. The use of antimicrobial-impregnated medical gloves could reduce the horizontal-transfer of bacterial contamination between surfaces. Determine the activity of antimicrobial-impregnated gloves against common hospital pathogens: Streptococcus pyogenes , carbapenem-resistant E.coli (CREC), MRSA and ESBL-producing Klebsiella pneumoniae . Fingerpads (~1cm 2 ) of PHMB-treated and untreated gloves were inoculated with 10 μL (~10 4 colony-forming-units [cfu]) of test-bacteria prepared in heavy-soiling (0.5%BSA), blood or distilled-water (no-soiling) and sampled after 0.25, 1, 10 or 15 min contact-time. Donor surfaces (~1cm 2 computer-keys) contaminated with wet/dry inoculum were touched with the fingerpad of treated/untreated gloves and subsequently pressed onto recipient (uncontaminated) computer-keys. Approximately 4.50log 10 cfu of all bacteria persisted after 15 min on untreated gloves regardless of soil-type. In the absence of soiling, PHMB-treated gloves reduced surface-contamination by ~4.5log 10 cfu (>99.99%) within 10 min of contact-time but only ~2.5log 10 (>99.9%) and ~1.0log 10 reduction respectively when heavy-soiling or blood was present. Gloves became highly-contaminated (~4.52log 10 –4.91log 10 cfu) when handling recently-contaminated computer-keys. Untreated gloves contaminated “recipient” surfaces (~4.5log 10 cfu) while PHMB-treated gloves transferred fewer bacteria (2.4–3.6log 10 cfu). When surface contamination was dry, PHMB gloves transferred fewer bacteria (0.3–0.6log 10 cfu) to “recipient” surfaces than untreated gloves (1.0–1.9log 10 ; P < 0.05). Antimicrobial-impregnated gloves may be useful in preventing dissemination of organisms in the near-patient environment during routine care. However they are not a substitute for appropriate hand-hygiene procedures.
20
Mary K. Hayden, Donald Blom, Elizabeth A. Lyle et al. · Infection Control and Hospital Epidemiology · 2007 · 297 citations
Surgical Glove Perforation and the Risk of Surgical Site Infection
Heidi Misteli · Archives of Surgery · 2009 · 208 citations · Full text