Wood and Fiber Science (Society of Wood Science and Technology) · 2007 · 39 citations · 6 references
Open access
EngineeringArchitectural EngineeringBuilding MaterialsFire Protection EngineeringThermal AnalysisFire Damage To WoodFire TestingFire-resistant MaterialsHeat Transfer In FiresMoisture Content AnalysisMoisture Dynamics In WoodBound Water AnalysisFire-induced Structural ResponseInitial Water ContentMoistureMoisture ContentMoisture Content DependenceMoisture Content EvaluationTransient Moisture Transport
Improved tire endurance design procedures for heavy timber members may require the input of moisture content-dependent allowable stresses.Therefore, experiments were conducted to characterize the transient moisture gradient in a wood slab subjected to fire on one face.Electrodes and thermocouples embedded within the wood sections monitored moisture and temperature levels at selected locations.Time-moisture content curves indicated an increase in moisture content that appeared to be associated with the vaporization of the bound water in the wood.For the eight slabs tested, the average peak moisture content was 1.26 to 2.00 times greater than the initial moisture content.
6