Journal of Vacuum Science and Technology · 1964 · 244 citations · 0 references
Natural SciencesElectrical EngineeringPhysicsElectromagnetismElectronic MaterialsSemiconductor DevicesElectric PotentialElectrical ConductivityAvalanche BreakdownBreakdown CharacteristicsBreakdown MechanismsElectric Field Thresholds For BreakdownElectrical BreakdownField EmissionLocal-field EffectsVacuum Conditions
The study reviews existing theories and experimental observations on the initiation of electrical breakdown. The mechanism attributes breakdown to field emission from sharp submicroscopic points, predicting failure when the local cathode field exceeds a critical value inferred from pre‑breakdown emission. Experiments extending prior data show that the critical breakdown field for tungsten is 6.5 × 10⁷ V/cm, independent of gap spacing or geometry up to 250 kV, supporting the field‑emission picture and explaining related phenomena.
Existing theories for the initiation of electrical breakdown are reviewed, together with the experimental observations on which they are based. Experiments here described have extended the available data on electrical breakdown between broad area electrodes under ultra-high-vacuum conditions. The results, together with those of several other experimenters, are interpreted on the basis of a single picture which explains and relates the phenomena of predischarge currents and the initiation of breakdown. Based on field emission from sharp submicroscopic points, this picture predicts breakdown when the local electric field at the cathode reaches a critical value. The local field, which for broad area electrodes may be much larger than the average field, is deduced from observations of field emission prior to breakdown. When properly analyzed, data for tungsten electrodes from this research and several others indicate a value for the electrical field at breakdown which is independent of gap spacing or geometrical configuration for voltages up to 250 kV. The critical breakdown field for tungsten is 6.5 × 107 V/cm. The above picture also gives physical insight into other phenomena associated with electrical breakdown.