The paper broadens the focus of transmission line pulse (TLP) data beyond I‑V curves. The paper describes a constant‑impedance transmission line pulse system with new measurement capabilities and improved accuracy. The system employs a constant‑impedance transmission line pulse design and introduces a calibration method and standard TLP test method for industry adaptation. Accurate TLP measurements and TLP/HBM device data demonstrate dV/dt effects, HBM/TLP correlation and miscorrelation, underscoring the need for correlation and repeatability of experimental data.

Abstract

This paper describes a constant impedance transmission line pulse system with new measurement capabilities and improved accuracy. The paper enforces a broader look at transmission line pulse (TLP) data, beyond the I-V curves. Accurate TLP measurements and actual TLP/HBM device data are used to demonstrate dV/dt effects and HBM/TLP correlation and miscorrelation. Finally, a calibration method and standard TLP test method are presented for adaptation by the industry. This is necessary to provide correlation and repeatability of experimental data.