Reliability improvement using buried capping layer in advanced interconnects

Kok-Yong Yiang, T.S. Mok, Won Jong Yoo, Ahila Krishnamoorthy

2004 · 11 citations · 3 references

Concepts

Abstract

Electrical leakage and breakdown characteristics of low-dielectric constant (low-k) dielectrics are increasingly becoming major reliability issues as inter-metals spacings in interconnects are scaled towards the 0.1 /spl mu/m technology node. These issues are greatly alleviated by the implementation of a buried capping layer (BCL) in Cu damascene structures. It is found that a BCL of 100 /spl Aring/ thickness in Cu/SiOC interdigitated comb structures reduces the leakage current by 1 order of magnitude and improves breakdown strength by a factor of 1.5 to 2. In addition, the BCL is able to suppress the formation of process-induced traps in the low-k dielectric. These findings can have important reliability considerations for Cu/low-k integration schemes.

References

3