PLoS ONE · 2011 · 44 citations · 31 references
Veterinary MedicineInfectious DiseasesMicrobiologyDiagnostic MicrobiologyMedical MicrobiologyMolecular DiagnosticsCulture-based DiagnosisNucleic Acid Amplification TestingPulmonary TuberculosisRapid Diagnostic TestsTuberculosis DiagnosisTuberculosis Diagnostic TestingLoop-mediated Isothermal AmplificationLoop-mediated Isothermal Amplification (Lamp)Nucleic Acid AmplificationPulmonary Tuberculosis DiagnosisRapid Diagnostic AssaysSensitivitySputum MicroscopySputum Smear Microscopy
BACKGROUND: Despite the advent of novel diagnostic techniques, smear microscopy remains as the most practical test available in resource-limited settings for tuberculosis (TB) diagnosis. Due to the low sensitivity of microscopy and the long time required for culture, feasible and accessible rapid diagnostic methods are urgently needed. Loop-mediated Isothermal Amplification (LAMP) is a promising nucleic-acid amplification assay, which could be accessible, cost-effective and more suited for use with unpurified samples. METHODOLOGY/PRINCIPAL FINDINGS: In the current study, the objective was to assess the efficacy of a LAMP assay for tuberculosis compared with fluorescence smear microscopy as well as Löwenstein-Jensen (LJ) and Mycobacteria Growth Indicator Tube (MGIT) cultures for the diagnosis of pulmonary tuberculosis using sputum samples. Smear microscopy and culture were performed for decontaminated and concentrated sputum from TB suspects and the LAMP was also performed on these specimens. The LAMP and smear microscopy were compared, in series and in parallel, to culture. LAMP and smear microscopy showed sensitivities of 79.5% and 82.1% respectively and specificities of 93.8% and 96.9% respectively, compared to culture. LAMP and smear in series had sensitivity and specificity of 79.5% and 100.0% respectively. LAMP and smear in parallel had sensitivity and specificity of 82.1% and 90.6% respectively. CONCLUSIONS/SIGNIFICANCE: The overall efficacies of LAMP and fluorescence smear microscopy in the current study were high and broadly similar. LAMP and smear in series had high specificity (100.0%) and can be used as a rule-in test combination. However, the performance of LAMP in smear negative samples was found to be insufficient.
31
Statistics Notes: Diagnostic tests 1: sensitivity and specificity
Douglas G. Altman, J Martin Bland · BMJ · 1994 · 2.1K citations · Full text
Clinical Epidemiology: The Essentials.
Annals of Internal Medicine · 1991 · 1.9K citations
Statistics Notes: Diagnostic tests 2: predictive values
Douglas G. Altman, J Martin Bland · BMJ · 1994 · 1.7K citations · Full text