Review of Scientific Instruments · 1999 · 17 citations · 26 references
Natural SciencesRadiologyPlasma PhysicsRadiation DosimetryRadiation MeasurementRadiographic ImagingX-ray DetectionX-ray DetectorsX-ray SpectroscopyElectron Cyclotron Resonance Plasma SourcesExperimental StudiesPlasma X-ray SourcesX-ray DiagnosticsX-ray DosimetryX-ray Imaging PhysicsX-ray Source CharacterizationX-ray Spectra
A compact electron cyclotron resonance plasma x-ray source, which has a potential use for medical imaging is presented in this article. In this article, the experimental system and the characterization studies on plasma and x ray are presented. Using a Langmuir probe, the plasma parameters are measured for different magnetic field profiles and gas pressures. The x-ray spectrum is obtained for various gas pressures and magnetic field profiles. In the x-ray spectrum, the Bremstrahlung radiation, peaking at 20–60 keV is observed and the final energy of the x ray is extended up to ∼200 keV. Thermo luminescence dosimeter (CaSO4 sample) is used for estimating the dose at the port and these results are presented for typical x-ray spectra. Using a teletector, the dose at the port for various coil current is measured and these are compared with the estimated dose obtained from the x-ray spectrum.
26
<i>Basic Data of Plasma Physics</i>
Sanborn C. Brown, Steve Singer · Physics Today · 1961 · 1.1K citations
N. Sakudo, K. Tokiguchi, H. Koike et al. · Review of Scientific Instruments · 1977 · 104 citations
Engineering, Electrical Engineering, Nuclear Engineering +15
A Personnel Dosimeter TLD Badge Based on CaSO4
K.G. Vohra, R.C. Bhatt, Bhuwan Chandra et al. · Health Physics · 1980 · 79 citations