Magnetic Resonance in Medicine · 1997 · 85 citations · 27 references
Natural SciencesBiophysicsRadiologyBiomedical ImagingDiagnostic ImagingSpectroscopyElectron Paramagnetic ResonanceElectron Spin Resonance SpectroscopyMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMagnetic Resonance Signal FormationMagnetic Resonance SpectroscopyFree Induction DecayIn Vivo Nmr SpectroscopyNuclear Magnetic Resonance StudiesParamagnetic SpeciesPulsed Electron Spin ResonanceSpin RelaxationSpin-spin RelaxationTwo-dimensional Imaging
EPR imaging of free radicals has been limited by sub‑microsecond spin‑spin relaxation times, but recent 10‑50 ns RF pulse technology enables time‑domain acquisition and FID detection at 300 MHz. The study aims to demonstrate time‑domain RF EPR spectroscopy and imaging for in vivo applications. FID signals from a water‑soluble narrow‑line spin probe were recorded in phantoms and in an anesthetized mouse, and 2‑D images were reconstructed using static field gradients and back‑projection. The images achieved sub‑0.7 mm resolution without motion artifacts, indicating that pulsed RF EPR imaging could enable high‑resolution 3‑D spatial and spectral‑spatial studies while reducing cardiac and lung motion artifacts.
Imaging of free radicals by electron paramagnetic resonance (EPR) spectroscopy using time domain acquisition as in nuclear magnetic resonance (NMR) has not been attempted because of the short spin-spin relaxation times, typically under 1 microsecond, of most biologically relevant paramagnetic species. Recent advances in radiofrequency (RF) electronics have enabled the generation of pulses of the order of 10-50 ns. Such short pulses provide adequate spectral coverage for EPR studies at 300 MHz resonant frequency. Acquisition of free induction decays (FID) of paramagnetic species possessing inhomogenously broadened narrow lines after pulsed excitation is feasible with an appropriate digitizer/averager. This report describes the use of time-domain RF EPR spectrometry and imaging for in vivo applications. FID responses were collected from a water-soluble, narrow line width spin probe within phantom samples in solution and also when infused intravenously in an anesthetized mouse. Using static magnetic field gradients and back-projection methods of image reconstruction, two-dimensional images of the spin-probe distribution were obtained in phantom samples as well as in a mouse. The resolution in the images was better than 0.7 mm and devoid of motional artifacts in the in vivo study. Results from this study suggest a potential use for pulsed RF EPR imaging (EPRI) for three-dimensional spatial and spectral-spatial imaging applications. In particular, pulsed EPRI may find use in vivo studies to minimize motional artifacts from cardiac and lung motion that cause significant problems in frequency-domain spectral acquisition, such as in continuous wave (cw) EPR techniques.
27
Free Radicals in Biology and Medicine
E.T. Land · International Journal of Radiation Biology · 1990 · 4.9K citations