Asymmetric fatigue and its endurance improvement in resistance switching of Ag–La<sub>0.7</sub>Ca<sub>0.3</sub>MnO<sub>3</sub>–Pt heterostructures

D. S. Shang, Lidong Chen, Quanfang Wang, Zhenhua Wu, W Q Zhang, X M Li

Journal of Physics D Applied Physics · 2007 · 11 citations · 18 references

Concepts

Abstract

The asymmetric fatigue behaviour of electric-pulse-induced resistance switching, that is, only switching from a low to a high resistance state, exhibits obvious fatigue behaviour and has been investigated in Ag–La0.7Ca0.3MnO3–Pt heterostructures. This asymmetric fatigue is strongly dependent on the applied electric-pulse voltage and can be refreshed by applying a voltage sweep in vacuum condition (<100 Pa). The fatigue and its refreshment are related to the increase and decrease in threshold voltage in the resistance switching, respectively. The results indicate that fatigue endurance in resistance switching of Ag–La0.7 Ca0.3MnO3–Pt heterostructures can be improved through the operation of environmental oxygen pressure.