Indirect performance sensing for on-chip analog self-healing via Bayesian model fusion

Shuyue Sun, F. Wang, Soner Yaldiz, X. Li, Larry Pileggi, Arun Natarajan, Mark Ferriss, Jean‐Olivier Plouchart, Bodhisatwa Sadhu, B. Parker,

2013 · 20 citations · 10 references

Concepts

Abstract

On-chip analog self-healing requires low-cost sensors to accurately measure various performance metrics. In this paper we propose a novel approach of indirect performance sensing based upon Bayesian model fusion (BMF) to facilitate inexpensive-yet-accurate on-chip performance measurement. A 25GHz differential Colpitts voltage-controlled oscillator (VCO) designed in a 32nm CMOS SOI process is used to validate the proposed indirect performance sensing and self-healing methodology. Our silicon measurement results demonstrate that the parametric yield of the VCO is improved from 0% to 69.17% for a wafer after the proposed self-healing is applied.