Applied Physics Letters · 2001 · 12 citations · 12 references
EngineeringElectrical EngineeringMaterials ScienceMicroelectronicsSemiconductor DevicesSemiconductor MaterialsField-effect TransistorsHigh-frequency Semiconductor DevicesScanning Probe MicroscopySemiconductor InterfacesSemiconductor PhysicsSemiconductor SurfacesHeterostructure DevicesHeterostructure Field-effect TransistorsHeterostructure TransistorsMicroscopy ImagingScanning Electron MicroscopySensitivitySpatial Resolution MeasurementTwo-dimensional Electron Gases
Charge-imaging field-effect transistors (FETs) were fabricated from a GaAs/AlGaAs heterostructure containing a near-surface two-dimensional electron gas. These FETs have quantum point contact geometries to minimize the size of the channel and to improve the spatial resolution. The charge noise at T=4.2 K has a 1/f behavior and reaches values ≪1e/Hz1/2 at 30 kHz. The spatial resolution of the FET was measured at liquid He temperatures using a scanned probe microscope with a charged tip. The charge sensitivity of the FET is confined to a disk with full width at half maximum 340 nm. These FETs are suitable for integration onto a GaAs/AlGaAs scanned probe microscopy cantilever.
12
Electromagnetic fields and waves
Choice Reviews Online · 1994 · 648 citations · Full text
Coherent branched flow in a two-dimensional electron gas
The Mathematical Theory of Electricity and Magnetism
Imaging Coherent Electron Flow from a Quantum Point Contact
M. A. Topinka, Brian J. LeRoy, S. E. J. Shaw et al. · Science · 2000 · 390 citations
Scanning Single-Electron Transistor Microscopy: Imaging Individual Charges
M. J. Yoo, T. A. Fulton, Harald F. Hess et al. · Science · 1997 · 322 citations