Cantilever unified theory and optimization for sensors and actuators

G. A. Gehring, M.D. Cooke, I. S. Gregory, W.J. Karl, R. K. Watts

Smart Materials and Structures · 2000 · 36 citations · 25 references

Concepts

Abstract

The deflection of a bilayered cantilever due to an external stimulus can be utilized in novel microsensors and actuators. It can also be used to determine the material properties of the components. Existing models are limited to investigations of individual systems such as isotropic (thermal, piezoelectric etc) or anisotropic (magnetostrictive) driving stimuli. A unified theory is presented based on total energy minimization, allowing inclusion of all stimuli acting on the system. Current theory, including that of a magnetostrictive cantilever, also tends to be related to a negligible film-to-substrate thickness ratio. This analysis allows examination of all thickness ratios, is in agreement with finite-element analysis, and also reduces to the thin-film limit. This is of increasing importance with the current drive to make micro devices.

References

25