Electrical breakdown in vacuum

R. P. Little, Scott T. Smith

IEEE Transactions on Electron Devices · 1965 · 32 citations · 22 references

Concepts

Abstract

Theories and experimental facts of vacuum breakdown are reviewed. Measurements with gap spacings of 0.015 inch indicate little or no variation of breakdown with tube pressure between approximately 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-5</sup> and 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-7</sup> torr and with frequency of the applied voltage from 0 to 6 Mc/s. Variation of electrode materials, geometry, and surface preparations provide no marked improvements, but high voltage aging or conditioning does improve the breakdown characteristics by a factor of as much as 2 to 1. Enhanced field emission, from whisker-like protrusions on the cathode surface, causes individual beams of field-emission prebreakdown current to flow from cathode to anode. This prebreakdown current can cause resistive heating of the protrusion and localized electron-bombardment anode heating both of which produce vaporization and destructive effects which could lead to breakdown.

References

22