Applied Physics Letters · 1975 · 83 citations · 4 references
EngineeringElectrical EngineeringMaterials ScienceSemiconductor DevicesSemiconductor MaterialsSpectroscopyDetector TechnologyGamma-ray DetectionGamma-ray DetectorsGamma-ray SpectroscopySemiconductor DetectorsSemiconductor PhysicsDetectorsGamma-ray Detector TechnologyGamma-ray SpectrometrySemiconductor Detector ResolutionSemiconductor Gamma-ray DetectorsSemiconductor Particle DetectorsSemiconductor Radiation Detectors
With the standard plane−parallel configuration of semiconductor detectors, good γ−ray spectra can only be obtained when both electrons and holes are completely collected. We show by calculations (and experiments) that with contacts of hemispherical configuration one can obtain γ−ray spectra of adequate resolution and with signal heights of nearly full amplitude even when only one type of carrier is collected. Experiments with CdTe detectors for which the μτ product for electrons is about 103 times that of the holes confirm these calculations. The adoption of hemispherical contacts thus widens the range of high−resistivity semiconductors potentially acceptable for γ−ray detection at room temperature.
4
Currents Induced by Electron Motion
Simon Ramo · Proceedings of the IRE · 1939 · 1.5K citations
K. Zanio, W. Akutagawa, H. Montano · IEEE Transactions on Nuclear Science · 1972 · 17 citations
Engineering, Electrical Engineering, Nuclear Engineering +15