Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 1997 · 13 citations · 11 references
EngineeringElectrical EngineeringMechanical EngineeringInstrumentationOpticsVibrationInterferometryOptical InstrumentsOptical MetrologyServo SystemsVibration ControlVibration MeasurementHigh-frequency MeasurementInterferometric MeasurementOptical InterferometersOptical InterferometryPhase MeasurementPhase Shifting InterferometryRelative PhaseStabilization
Phase shifting interferometry requires an intentional shifting of the relative phase between the reference arm and the test arm of fan interferometry. Vibration can lead to uncertainty in the relative phase difference with respect to time and result in erroneous surface measurements. We have developed a method for actively compensating for vibration using a closed-loop phase servo system. An essential feature of this is a high frequency phase measurement. The phase is modulated and the intensity variations are measured with a high sped photodiode and digitized. This information is processed by a DSP and a five step algorithm is used to determine the instantaneous phase. These high speed phase measurements are used in a closed loop phase servo to compensate for vibration and also allow for phase shifting interferometry. Test results with and without the vibration compensation will be presented.
11
Using diode lasers for atomic physics
Carl Wieman, L. Hollberg · Review of Scientific Instruments · 1991 · 798 citations