Applied Physics Letters · 2012 · 31 citations · 18 references
EngineeringMicroscopySilicon On InsulatorCalibrationOptical PropertiesInstrumentationRadiation ImagingRadiologyHealth SciencesSemiconductor Device FabricationRadiometryCrystalline Silicon WafersQuantitative Lic LifetimeSilicon DebuggingIngaas CameraSilicon WafersApplied PhysicsBiomedical ImagingQuantitative Phase ImagingOptical EngineeringOptoelectronics
Quantitative self-calibrating lock-in carrierography (LIC) imaging of crystalline silicon wafers is introduced using an InGaAs camera and a spread super-bandgap illumination laser beam. Images at several modulation frequencies and a simplified model based on photocarrier radiometric theory are used to construct the effective carrier lifetime image from the phase-frequency dependence. The phase image data at several frequencies and at selected locations on a wafer were compared to frequency scans obtained with a single-element InGaAs detector, and good agreement was found. The quantitative LIC lifetime imaging capability demonstrated in this work is self-calibrating and eliminates the requirement for calibration in conventional photoluminescence imaging.
18
Photoluminescence imaging of silicon wafers
Thorsten Trupke, R.A. Bardos, Martin C. Schubert et al. · Applied Physics Letters · 2006 · 655 citations
D.K. Schroder · IEEE Transactions on Electron Devices · 1997 · 434 citations
Materials Science, Semiconductors, Electrical Engineering +13
Andreas Mandelis, Jerias Batista, Derrick Shaughnessy · Physical review. B, Condensed matter · 2003 · 166 citations