Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 1999 · 22 citations · 0 references
Natural SciencesPhysicsMetrologyOpticsForm MeasurementInterferometryOptical MetrologyPhysical OpticsSpherical GeometryAccuracyInterferometric MeasurementInterferometric MetrologyInterferometric Surface MeasurementOptical Displacement MeasurementOptical InterferometersOptical InterferometrySurface Measurement Uncertainty
Absolute measurement of spherical surface by use of point diffraction interferometer (PDI) has been studied both theoretically and experimentally. By the estimation of optical error, 10<SUP>-3</SUP> (lambda) rms can be expected as absolute accuracy. Experimental results with high accuracy have been obtained.