Applied Optics · 2003 · 34 citations · 12 references
EngineeringMaterials EngineeringMetrologyMicrofabricationOpticsDisplay TechnologiesInterferometryLiquid CrystalsOptical MetrologyDepth SensingFringe AnalysisLiquid Crystal DisplaysMicroscope ImagingNematic Liquid CrystalsOptical ProfilometryPhase Shifting MechanismsProfilometry
When three dimensional measurements are conducted with fringe projection, the quality of the grating used for the generation of the fringes is important. It has a direct influence on the achievable depth resolution in a given measurement setup. In the past, Ronchi grating or gratings written in nematic liquid-crystal displays or in digital micromirror devices have been used. We report on the application of a reflective ferroelectric liquid-crystal-on-silicon display as the fringe-generating element in a setup based on a stereo microscope. With this device the depth resolution of measurements by use of phase-shifting algorithms can be significantly improved compared with the application of a Ronchi grating or a nematic liquid-crystal display.
12
Digital wave-front measuring interferometry: some systematic error sources
Johannes Schwider, R. Burow, K.-E. Elßner et al. · Applied Optics · 1983 · 712 citations