IEEE Transactions on Instrumentation and Measurement · 2014 · 26 citations · 10 references
EngineeringElectrical EngineeringCircuit TheoryPower ElectronicsUncertainty QuantificationCurrent-voltage CharacteristicsDevice SimulationElectric CircuitsElectrical MeasurementElectronics TechnologySmall-signal AnalysisAngle Error AnalysisCurrentsElectric Circuit ModelsPhase AngleProbabilistic Uncertainty AnalysisSmall-signal Equivalent Circuit Models
This paper describes mathematical modeling of cage-type ac current shunts. A calculable model was developed using lumped circuit elements. The transimpedance, ac-dc difference, and the phase angle error of a shunt can be derived from the model. An uncertainty analysis of the model was done by means of Monte Carlo methods. Comparison of the calculated and measured values shows an agreement better than 6 μΩ/Ω in the ac-dc difference and 110 μrad in the phase angle error at frequencies up to 100 kHz.
10
Expanding the Measurement Capability for AC-DC Current Transfer at BEV
M. Garcocz, P. Scheibenreiter, W. Waldmann et al. · 2004 · 34 citations