Direct Measurement of AC Current by Measuring the Voltage Drop on the Coaxial Current Shunt

Boštjan Voljč, Matjaž Lindic, R. Lapuh

IEEE Transactions on Instrumentation and Measurement · 2008 · 40 citations · 6 references

Concepts

Abstract

<para xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> An accurate direct measurement of ac current that avoids complex and time-consuming ac–dc current transfer measurements by directly measuring the ac voltage drop of coaxial current shunts is described. Evaluation of custom-developed coaxial current shunts for long-term drift, self-heating effects, and loading using a commercial ac voltmeter is presented. By correcting only the shunts' long-term drift, direct ac current measurement uncertainties below 55 <formula formulatype="inline"><tex Notation="TeX">$\mu\hbox{A/A}$</tex></formula> are attained in the frequency range of 20 Hz–30 kHz and for currents ranging from 100 mA up to 10 A. </para>

References

6