2004 · 34 citations · 2 references
EngineeringElectrical EngineeringInstrumentationMetrologyPower ElectronicsCurrent Measurement InstrumentsCurrent-voltage CharacteristicsElectrical MeasurementMeasurement StandardsCurrent MeasurementCurrent Measurement AccuracyCurrent Meter DesignCurrent Meter MeasurementsMeasurement System CapabilityPower MeasurementShunt Measurement
To expand the measurement capability up to 100 A at 100 kHz a construction for current shunts and Tee-connectors has been made, calculated and manufactured up to 40 A until now
2