Applied and Environmental Microbiology · 1976 · 25 citations · 12 references
EngineeringEnvironmental EngineeringMicrobiologyWastewater TreatmentWater Quality EngineeringWater TreatmentEffluent TreatmentMembrane FiltrationResource Recovery From WastewaterWastewater BiotreatmentWastewater MicrobiologyWastewater Resource RecoveryColiform BacteriaEnrichmentMembrane Filtration In Water TreatmentSewage ContaminantsTotal ColiformsWastewater Treatment MembranesWastewater Treatment PlantsWater Treatment Membranes
The standard one-step M-FC broth-membrane-filter procedure for recovery of fecal coliforms from chlorinated sewage effluents is much less effective than the multiple-tube (most-probable-number) technique. A two-step membrane-filter method, using a pre-enrichment technique with phenol red lactose broth and incubation at 35 degrees C for 4 h, followether 18+/-2 h, enhanced fecal coliform recovery from chlorinated effluents. The results of 126 comparisons using chlorinated effluents from five wastewater plants showed that fecal coliform recovery by using the two-step membrane-filter method is comparable to that using the multiple-tube procedure.
12
Optimum Membrane Structures for Growth of Coliform and Fecal Coliform Organisms
K. J. Sladek, R. V. Suslavich, Bo-Kyoon Sohn et al. · Applied Microbiology · 1975 · 47 citations · Full text
Injury of Bacteria by Sanitizers
D. L. Scheusner, F. F. Busta, M. L. Speck · Applied Microbiology · 1971 · 43 citations · Full text