American Journal of Neuroradiology · 2024 · 14 citations · 23 references
MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyNeuroradiologyBrain ImagingComputed TomographyDiagnostic ErrorMagnetic Resonance ImagingMeasurement ErrorMedical ImagingAdaptive Intervention AlgorithmsAdaptive Intervention DesignAdaptive Intervention EvaluationAdaptive Intervention PlanningClinical Workflow ManagementError Rate AnalysisRadiology ErrorsVolume Shift
<h3>BACKGROUND AND PURPOSE:</h3> Unlike in Europe and Japan, guidelines or recommendations from specialized radiological societies on workflow management and adaptive intervention to reduce error rates are currently lacking in the United States. This study of neuroradiologic reads at a large US academic medical center, which may hopefully contribute to this discussion, found a direct relationship between error rate and shift volume. <h3>MATERIALS AND METHODS:</h3> CT and MR imaging reports from our institution’s Neuroradiology Quality Assurance database (years 2014–2020) were searched for attending physician errors. Data were collected on shift volume specific error rates per 1000 interpreted studies and RADPEER scores. Optimal cutoff points for 2, 3 and 4 groups of shift volumes were computed along with subgroups’ error rates. <h3>RESULTS:</h3> A total of 643 errors were found, 91.7% of which were clinically significant (RADPEER 2b, 3b). The overall error rate (errors/1000 examinations) was 2.36. The best single shift volume cutoff point generated 2 groups: ≤ 26 studies (error rate 1.59) and > 26 studies (2.58; OR: 1.63, <i>P</i> < .001). The best 2 shift volume cutoff points generated 3 shift volume groups: ≤ 19 (1.34), 20–28 (1.88; OR: 1.4, <i>P</i> = .1) and ≥ 29 (2.6; OR: 1.94, <i>P</i> < .001). The best 3 shift volume cutoff points generated 4 groups: ≤ 24 (1.59), 25–66 (2.44; OR: 1.54, <i>P</i> < .001), 67–90 (3.03; OR: 1.91, <i>P</i> < .001), and ≥ 91 (2.07; OR: 1.30, <i>P</i> = .25). The group with shift volume ≥ 91 had a limited sample size. <h3>CONCLUSIONS:</h3> Lower shift volumes yielded significantly lower error rates. The lowest error rates were observed with shift volumes that were limited to 19–26 studies. Error rates at shift volumes between 67–90 studies were 226% higher, compared with the error rate at shift volumes of ≤ 19 studies.
23
Epidemiology of Anesthesia-related Mortality in the United States, 1999–2005
Guohua Li, Margaret Warner, Lin Huang et al. · Anesthesiology · 2009 · 405 citations · Full text
Miss Rate of Lung Cancer on the Chest Radiograph in Clinical Practice
Lorentz G.B.A. Quekel, Alphons G.H. Kessels, R Goei et al. · CHEST Journal · 1999 · 315 citations
On the Scientific Evaluation of Diagnostic Procedures
L. Henry Garland · Radiology · 1949 · 238 citations