IEEE Transactions on Transportation Electrification · 2023 · 16 citations · 25 references
EngineeringElectrical EngineeringFault ToleranceFault-tolerant SystemsPower ElectronicsDiagnosisDiagnosticsElectrical System DiagnosticsFault DetectionFault DiagnosisSynchronous MachinesElectric Motor Fault DiagnosisFault Diagnosis AlgorithmsIncipient Fault DetectionMachine Fault DiagnosisOperating ConditionsPermanent Magnet Synchronous MachinesPermanent Magnet Synchronous MotorsPhase Angle
Interturn short fault (ISF) and high-resistance connection fault (HRC) are both common incipient faults occurred in permanent magnet synchronous machines (PMSMs). Due to the different severity of these two faults, in addition to the conventional fault diagnosis, it is necessary to distinguish the fault type, so as to take targeted preventive measures. To ensure the reliability of PMSM system, a novel method for detecting and discriminating ISF fault and HRC fault in PMSM based on the deviation angle of zero-sequence voltage component (ZSVC) is proposed in this paper. In this method, the amplitude and initial phase angle of ZSVC are both analyzed by an improved phasor tracking algorithm. The amplitude of ZSVC is used to detect the abnormal operation of the PMSM, and the discrimination indicator (DI) is constructed using the phase angle of ZSVC and three-phase current to distinguish these two faults. The simulation and experiments are carried out to verify the effectiveness of theoretical analysis, and the results show that the proposed method has good performance under different operating conditions and fault severities.
25