Microbiology Spectrum · 2023 · 11 citations · 24 references
MedicineInfectious DiseasesMicrobiologyDiagnostic MicrobiologyMedical MicrobiologyMolecular DiagnosticsCrispr-cas SystemsInfectious Disease DetectionInfectious Disease Molecular TestingMolecular DiagnosisNucleic Acid Amplification TestingPathogen DetectionCrispr DiagnosticsCrispr-based Molecular DiagnosticsMultiplex Amplification AssaysMultiplex Polymerase Chain Reaction (Pcr)Multiplex Polymerase Chain Reaction AssaysPcr-based DetectionPolymerase Chain Reaction DetectionRecombinase Polymerase Amplification
ABSTRACT The occurrence of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) is increasing worldwide, particularly in low- and middle-income countries. In cases where most infections are asymptomatic and remain in a coinfection condition. It may cause missed detections or the severe subsequent symptoms. Accurate diagnosis and convenient screening are essential for disease control. However, molecular diagnostics for CT/NG predominantly rely on polymerase chain reaction (PCR)-based detection, which requires special devices and conditions. Here, we developed an isothermal CRISPR-based CT/NG dual-target detection system by pairing recombinase polymerase amplification (RPA) and CRISPR-Cas12a/13a detection. Multiplex RPA can amplify NG and CT simultaneously, and a single-pot reaction with the Cas12a/13a can be performed for further recognizing the amplified target, driving the cleavage of the corresponding fluorescence reporter separately; thus, the signal can be monitored in different channels. This CRISPR-based CT/NG detection system achieved analytical sensitivities of 10° copies/μL for both synthetic CT/NG dsDNA and exhibited no cross-reaction with other species. In tests on 88 clinical samples, our CRISPR-based assay showed excellent agreement with the commercial assay Roche Cobas 4800 (100% accuracy for NG, 94.32% accuracy for CT, and 97.73% accuracy for CT/NG coinfection) and showed higher positive percent agreement, negative percent agreement, and accuracy than those reported for TaqMan PCR in a previous study. In addition, the results of this CRISPR-based system could be acquired within 75 min. Our isothermal diagnostic method with promising performance provides more convenience than PCR-based methods for detection and screening. IMPORTANCE A method for Neisseria gonorrhoeae (NG)/ Chlamydia trachomatis (CT) detection is developed using multiplex-recombinase polymerase amplification and Cas12a/Cas13a. This method can detect NG and CT simultaneously with high sensitivity and specificity. This method has great potential to be further developed into larger-scale screening and point-of-care testing (POCT).
24
CRISPR-Cas12a target binding unleashes indiscriminate single-stranded DNase activity
Janice S. Chen, Enbo Ma, Lucas B. Harrington et al. · Science · 2018 · 4.4K citations
Nucleic acid detection with CRISPR-Cas13a/C2c2
Jonathan S. Gootenberg, Omar O. Abudayyeh, Jeong Wook Lee et al. · Science · 2017 · 3.8K citations · Full text
C2c2 is a single-component programmable RNA-guided RNA-targeting CRISPR effector
Omar O. Abudayyeh, Jonathan S. Gootenberg, Silvana Konermann et al. · Science · 2016 · 2.4K citations · Full text