Computer Methods in Biomechanics & Biomedical Engineering · 2023 · 17 citations · 18 references
EngineeringNeuroscienceRehabilitation MedicineNeural EngineeringNeurorehabilitationRehabilitationElectroencephalogram AnalysisElectroencephalogram Signal ProcessingElectroencephalographyMovement KinematicsNeural DecodingNeurorehabilitation EngineeringBioelectrical Signal DecodingBrain-computer Interface Signal ProcessingEeg Signal ProcessingKinematic ReconstructionLower Extremity KinematicsReal-time Brain-computer Interface SystemsUnscented Kalman FilterUnscented Kalman Filtering
Kinematic reconstruction of lower-limb movements using electroencephalography (EEG) has been used in several rehabilitation systems. However, the nonlinear relationship between neural activity and limb movement may challenge decoders in real-time Brain-Computer Interface (BCI) applications. This paper proposes a nonlinear neural decoder using an Unscented Kalman Filter (UKF) to infer lower-limb kinematics from EEG signals during pedaling. The results demonstrated maximum decoding accuracy using slow cortical potentials in the delta band (0.1-4 Hz) of 0.33 for Pearson's r-value and 8 for the signal-to-noise ratio (SNR). This leaves an open door to the development of closed-loop EEG-based BCI systems for kinematic monitoring during pedaling rehabilitation tasks.
18
Unscented Kalman Filter for Brain-Machine Interfaces
Zheng Li, Joseph E. O’Doherty, Timothy Hanson et al. · PLoS ONE · 2009 · 185 citations · Full text