PharmacyPharmaceutical AnalysisPharmacologyMass Spectrometric AnalysisPharmacokinetic VariabilityPopulation PharmacokineticsBioanalytical Method ValidationLiquid ChromatographyAccuracyAnalytical Methods DevelopmentBioanalytical ApplicationsBlood Sample CollectionHematocrit EffectsHome Sample CollectionMethod Accuracy AssessmentReference Method Validation
BACKGROUND: Frequent blood phenylalanine (Phe) measurement is required for phenylketonuria (PKU) patients for diagnosis and disease status monitoring. Though various methods are available for blood Phe measurement, there is a lack of validated quantitative methods for measuring Phe with less than 15% variability. A method to allow at home blood sample collection for the PKU community is in high demand. METHODS: A volumetric absorptive microsampling (VAMS) dried blood collection high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed and fully validated for blood Phe measurement in compliance with regulatory guidances. The method accuracy, precision, stability, selectivity, matrix and hematocrit effects were assessed. A venous plasma collection HPLC-MS/MS method was developed and validated as a reference method. 311 matching VAMS and plasma samples were collected from 24 PKU subjects in a Phase 2 clinical study. Phe measurements using the two methods were compared. RESULTS: Both VAMS and the plasma sample collection methods met the acceptance criteria for Good Laboratory Practice (GLP) bioanalytical analysis. Comparisons showed a high Pearson's correlation of 0.9813. The Passing-Bablok analysis showed that the difference was estimated to be less than 5% and Bland Altman analysis indicated that the difference was proportional with Phe concentration and for the majority of samples (88.85%) the measurement was within ±20% difference. Following 7 days treatment with 60 or 20 mg/kg/day PTC923 (Sepiapterin) or 20 mg/kg/day sapropterin, PKU patients exhibited respectively -206.4, -146.9, and -91.5 µmol/L reductions of blood Phe as measured by the VAMS method. CONCLUSIONS: Concordant results were obtained using VAMS and plasma methods, which demonstrated that VAMS is a reliable method for clinical applications to monitor blood Phe for PKU patients.
28
Phenylalanine hydroxylase deficiency: diagnosis and management guideline
Jerry Vockley, Hans C. Andersson, Kevin M. Antshel et al. · Genetics in Medicine · 2014 · 722 citations · Full text
Barbara K. Burton, Dorothy K. Grange, Andrzej Milanowski et al. · Journal of Inherited Metabolic Disease · 2007 · 171 citations