Chemie Ingenieur Technik · 2023 · 16 citations · 24 references
EngineeringChemical EngineeringBioprocess EngineeringBioreactor DesignTransport PhenomenaBioreaction EngineeringBubble DynamicsGas TransferOxygen TransferTransport In BioreactorsBubble Column BioreactorsBubble DistributionBubble Size DistributionColumnsHoldupInterfacial AreaMass Transfer Across Bubble InterfacesOxygen Transfer Modeling
Abstract A comprehensive experimental characterization of a small‐scale bubble column bioreactor (60 mL) is presented. Bubble size distribution (BSD), gas holdup, and k L a were determined for different types of liquids, relevant fermentation conditions and superficial gas velocities u G . The specific interfacial area a and liquid mass transfer coefficient k L have been identified independent of each other to unravel their individual impact on k L a . Results show that increasing u G leads to larger bubbles and higher gas holdup. As both parameters influence a in opposite ways, no increase of a with u G is found. Furthermore, k L increases with increasing bubble size outlining that improved oxygen transfer is not the result of higher a but of risen k L instead. The results build the foundation for further simulative investigations.
24
Design parameters estimations for bubble column reactors
Y. T. Shah, B.G. Kelkar, S. P. Godbole et al. · AIChE Journal · 1982 · 1.2K citations
Nigar Kantarci, Fahir Borak, Kutlu Ö. Ülgen · Process Biochemistry · 2005 · 1K citations
Drag Coefficients of Single Bubbles under Normal and Micro Gravity Conditions.
Akio Tomiyama, Isao KATAOKA, Iztok Žun et al. · JSME International Journal Series B · 1998 · 722 citations · Full text