Food ChemistryBiochemistryFood QualityFlavoromicsMedicineBioanalysisMass SpectrometryApple Juice SampleFood AnalysisAnalytical ChemistryLiquid ChromatographyRipeningApple JuiceChromatographyAcetate DerivativeBiomolecular EngineeringFood SafetyHealth Sciences
Abstract The apple juice sample is extracted with ethyl acetate and the extract is cleaned up by elution from a silica gel column with ethyl acetate-benzene. Patulin is determined by use of a liquid chromatograph, a 25 cm Zorbax-Sil column, and a 254 nm ultraviolet detector. This method has a lower detection limit of 11 μg/L with recoveries of patulin added to apple juice >85%. Gas chromatographic-mass spectrometric analysis of the acetate derivative is used for confirmation. Patulin was detected at levels ranging from 44 to 309 μg/kg in 8 of 13 commercial samples of apple juice.